System SP1-xxx 
D086/D087 3-38 SM Appendix 
 
1950 
[Fan Cooling Time Set] 
Adjust the rotation time for each fan motor after a job end.   
002  Fusing Exit Fan  *ENG 
[0 to 120 / 0 / 0.1 min./step] 
006  Main Suction Fan  *ENG 
007  Paper Exit Fan  *ENG 
008 PSU Fan  *ENG 
009  Fusing IH Coil Fan  *ENG 
010  IH Power Supply Fan  *ENG 
011  Second Duct Fan  *ENG 
012  Third Duct Fan  *ENG 
 
1951 
[Fan Start Time Set] 
Adjust the start time for each fan motor after a job end.   
002  Fusing Exit Fan  *ENG 
[0 to 900 / 0 / 1 sec/step] 
006  Main Suction Fan  *ENG 
[0 to 900 / 120 / 1 sec/step] 
007  Paper Exit Fan  *ENG 
[0 to 900 / 0 / 1 sec/step] 
008 PSU Fan  *ENG 
[0 to 900 / 120 / 1 sec/step] 
009  Fusing IH Coil Fan  *ENG 
[0 to 900 / 0 / 1 sec/step] 
010  IH Power Supply Fan  *ENG 
011  Second Duct Fan  *ENG 
012  Third Duct Fan  *ENG