Main SP Tables-1
SM 5-37 D086/D087
System
Maintenance
1902 [Amplitude Control]
001 Execute - Execute the drum phase adjustment.
002 Result *ENG
[0 to 3 / 0 / 1]
Displays the result of the drum phase
adjustment.
0: Successfully done
2: Sampling failure
3: Insufficient detection number
003 Auto Execution *ENG
[0 or 1 / 1 / -]
Turns the automatic drum phase adjustment on
or off.
0: Off, 1: On
1950
[Fan Cooling Time Set]
Adjust the rotation time for each fan motor after a job end.
002 Fusing Exit Fan *ENG
[0 to 120 / 0 / 0.1 min./step]
006 Main Suction Fan *ENG
007 Paper Exit Fan *ENG
008 PSU Fan *ENG
009 Fusing IH Coil Fan *ENG
010 IH Power Supply Fan *ENG
011 Second Duct Fan *ENG
012 Third Duct Fan *ENG