System SP1-xxx
D086/D087 3-4 SM Appendix
1101
[Reload Permit Setting]
Specifies the settings of the reload permit for cold temperature in color mode.
001
Pre-rotation Start Temp. *ENG
[0 to 200 / 0 / 1 deg/step]
Specifies the pre-rotation start temperature.
002
Reload Target Temp.:Center *ENG
[120 to 180 / 150 / 1 deg/step]
Specifies the reload target temperature of the heating roller.
003
Reload Target Temp.:Press *ENG
[0 to 200 / 120 / 1 deg/step]
Specifies the reload target temperature of the pressure roller.
004
Temp.:Delta:Cold:Center *ENG
[0 to 200 / 5 / 1 deg/step]
Specifies the temperature correction of the heating roller (center) when the fusing
unit is determined as cold state.
005
Temp.:Delta:Cold:End *ENG
[40 to 200 / 100 / 1 deg/step]
Specifies the temperature correction of the heating roller (end) when the fusing unit
is determined as cold state.
006
Temp.:Delta:Cold:Press *ENG
[0 to 200 / 65 / 1 deg/step]
Specifies the temperature correction of the pressure roller when the fusing unit is
determined as cold state.
007
Time:Cold *ENG
[0 to 100 / 30 / 1 sec/step]
Specifies the threshold time for the fusiing reload when the fusing unit is
determined as cold state.
008
Temp.:Delta:Warm:Center *ENG
[0 to 200 / 5 / 1 deg/step]
Specifies the temperature correction of the heating roller (center) when the fusing
unit is determined as warm state.