System SP1-xxx
D086/D087 3-6 SM Appendix
017
Temp.:Delta:Cold:BW:End *ENG
[40 to 200 / 100 / 1 deg/step]
Specifies the temperature correction of the heating roller (end) in the black and
white mode when the fusing unit is determined as cold state.
018
Temp.Delta:Cold:BW:Press *ENG
[0 to 200 / 70 / 1 deg/step]
Specifies the temperature correction of the pressure roller in the black and white
mode when the fusing unit is determined as cold state.
019
Time:Cold:BW *ENG
[0 to 100 / 30 / 1 sec/step]
Specifies the threshold time for the fusing reload in black and white mode when the
fusing unit is determined as cold state.
020
Temp.:Delta:Cold:BW2:Center *ENG
[0 to 200 / 15 / 1 deg/step]
Specifies the temperature correction of the heating roller (center) in the black and
white mode when the fusing unit is determined as warm state.
021
Temp.:Delta:Cold:BW2:End *ENG
[40 to 200 / 100 / 1 deg/step]
Specifies the temperature correction of the heating roller (end) in the black and
white mode when the fusing unit is determined as warm state.
022
Temp.Delta:Cold:BW2:Press *ENG
[0 to 200 / 100 / 1 deg/step]
Specifies the temperature correction of the pressure roller in the black and white
mode when the fusing unit is determined as warm state.
023
Time:Cold:BW2 *ENG
[0 to 100 / 30 / 1 sec/step]
Specifies the threshold time for the fusing reload in black and white mode when the
fusing unit is determined as warm state.