SM 5-31 G147
Service
Tables
[0~1/1]
0: Off
1: On. Sets the tray for feeding paper up to 600 mm long.
If this SP is set to ‘on’, paper jams are not detected in the paper path.
By-pass Tray Pap Bypass Paper Size Error
5179
This SP determines whether a paper size error prompt appears when the
machine detects the wrong paper size for the job and jams during feed from the
bypass tray.
[0~1/0/1]
0: Off
1: On
Set Time DFU
5302
Sets the time clock for the local time. This setting is done at the factory before
delivery. The setting is GMT expressed in minutes.
[–1440~1440/1 min.]
JA: +540 (Tokyo)
NA: -300 (NY)
EU: +6- (Paris)
CH: +480 (Peking)
TW: +480 (Taipei)
AS: +480 (Hong Kong)
Summer Time
5307
Lets you set the machine to adjust its date and time automatically with the
change to Daylight Savings time in the spring and back to normal time in the fall.
This SP lets you set these items:
- Day and time to go forward automatically in April.
- Day and time to go back automatically in October.
- Set the length of time to go forward and back automatically.
The settings for 002 and 003 are done with 8-digit numbers: