Options
SM 1-31 J012/J013/J014
Installation
Never remove the duplex unit from the back of the machine.
The duplex unit is part of the paper feed path and must be installed, even if the
customer is not doing duplex printing.
Set Paper Type and Size for the Multi Bypass Tray
Do the Paper Type/Size Setting for the Multi Bypass Tray
1. [Menu] > "System Settings?"
2. [#] or [%] > "Tray Paper Setting?"> [Yes]> "Tray1?"
3. [#] or [%] > "Bypass Tray"
4. [Yes] > "Paper Type?"> [Yes]> "Plain Paper?"
5. [#] or [%] > Select the type of paper that will be loaded the Multi Bypass Tray.
6. [Yes] > "Tray Paper Setting?"> [Yes] "Tray1?"
7. [#] or [%] > "Bypass Tray"
8. [#] or [%] > "Paper Size?> [Yes]
9. [#] or [%] > Select the size of paper that will be loaded in the Multi Bypass Tray.
10. [Yes] > "Tray Paper Setting?"
11. [Clear Modes]> Standby
12. Cycle the machine off/on.
1.4.3 NETWORK INTERFACE BOARD J510
The Network Interface Board J510 is an option for the J012 and J013 machines only.
The network board is built into the J014.
Install the NIB
1. Check the type of machine to be installed:
The network interface board is built into the J014, so the installation procedure
described below is not necessary for the J014.
However, the Network Interface Board J510 is an option for the J012/J013 and
must be installed for network connectivity.