Cleaning Procedures
SM 3-63 J012/J013/J014
Replacement
Adjustment
3.10.3 FEED ROLLER CLEANING
Preparation:
Remove platen or ADF. ( 3.2.4, 3.2.5)
Raise the scanner unit to full upright. ( 3.2.7)
Remove: (1) paper cassette, (2) paper output tray ( 3.2.8)
1. Remove the flushing unit [1] (x1).
2. Use the tip of a long flat-head screwdriver to release the Teflon lock tab [2] of the
transport roller.
3. Push the transport roller gear [3] to the left. This unlocks the roller and allows it to rotate
freely.
4. Rotate the roller and clean it with a dry cloth.
Be sure to lock the roller in place after cleaning.