Setting Items
Default
Value
Max.
Value
Min.
Value
Step Unit
RollerSpeed: Scratch: Short
RollerSpeed: Scratch: Long
Roller Speed: Uneven Gloss
100 100 50 1 -
Smoothing Time: Scratch 120 60000 0 1 -
Smooth.Time: Uneven Gloss 10 60000 0 1 -
0511 Fuser Unit Speed Adjustment
Perform adjustment to correct the deviation in the Fuser Unit rotation speed, and adjust the speed to an
appropriate value.
This process will take approximately 5 minutes to complete. A message appears on the control panel
while the process is being executed. Keep the front cover of the main unit closed until the process is
completed.
Setting Items Description
Execute Press [Execute] to execute the function.
0514 Temperature / Humidity Inside
Display the internal temperature and humidity.
Report this information if your service representative requests it.
Setting Items Remarks
PCU Temperature
PCU Humidity
Machine Temperature
Value display only.
0515 Temperature / Humidity Outside
Display the external temperature and humidity.
Report this information if your service representative requests it.
Setting Values
301