Setting Items
Default
Value
Max.
Value
Min.
Value
Step Unit
Img Magn: With Feed 0.0 5.0 -5.0 0.1 %
0311 Buffer Pass Unit Fan Activation Setting
Select the condition for activating the fan in the Cool Feeding Unit. When the fan stops, the mechanical
noise is lower.
Setting Items Values Default Value
Set All Paper Weights
Weight 3 or
Heavier
Weight 4 or
Heavier
Weight 5 or
Heavier
Weight 6 or
Heavier
Off
Weight 3 or Heavier
• Stopping the fan deteriorates the cooling capacity and may cause blocking to occur.
Machine: Maintenance
0501 Execute Process Adjustment
Execute the following adjustments for printing at once:
• image density, color deviation, charge roller cleaning, charge bias, and transfer current correction
Setting Items Description
Execute Press [Execute] to execute the function.
7. Adjustment Settings for Operators