DFG008
• Open the multi-folding
unit front cover.
• Turn knob N6 15 to 16
times clockwise.
• Turn knob N5 15 to 16
times clockwise.
• Pull lever N7 to the
right.
• Remove misfed paper.
• Turn knob N8 21 to 22
times clockwise.
• Remove misfed paper.
• Return lever N7 to its
original position.
• Pull handle N9 and pull
the unit fully out.
• Pull lever N10 towards you,
and then check the lock is
released.
• Leave cover N10 in its
open position.
• Remove misfed paper
from inside.
• Close cover N10.
• Pull lever N10 towards you and
hold it to release the lock, and
then pull the lever to the right to
open cover N10 as shown in
the illustration below.