When Rb12 – Rb13 is displayed (when Finisher SR5050 is installed)
• Open the finisher front
cover.
• Pull handle Rb12, and
then pull out the
staple unit.
• Raise lever Rb13, and then remove misfed
paper.
• Return lever Rb13 to its original position.
• Return the staple unit to its original position,
and then close the finisher front cover.
CXG033
When Rb1 – Rb5 is displayed (when Booklet Finisher SR5060 is installed)
• Open the finisher front
cover.
• Raise lever Rb1, and
then remove misfed
paper.
• Turn knob Rb2, and
then remove misfed
paper.
• Return lever Rb1 to its
original position.
• Turn lever Rb4 to the
right, and then
remove misfed paper.
• Return lever Rb4 to its
original position.
• Raise lever Rb5 to the right, and then
remove misfed paper.
• Return lever Rb5 to its original position.
• Close the finisher front cover.
• Raise lever Rb3, and
then remove misfed
paper.
• Return lever Rb3 to its
original position.
CXG022
11. Troubleshooting
508