217
Performance:
The function calculates the cos and the sin to the nearest 0.0001 by rounding up or down as appropriate.
Sin (63°8) = 0.8973 and Cos (63°8) = 0.4415
5.5.62 Absolute Humidity
Fashion: Classic:
Short Description
This function is used to calculate the absolute humidity.
Connection
Description
Input En
Enable the function
Input T
Temperature
Output RH
Humidity
Output AQ
Absolute humidity
Calculate rule: