4. BASIC OPERATION
IMR02C15-E4
4-3
Parameter Setting Mode
F01 to F10 indicate group numbers used in Non-display of block and Set lock level in Engineering mode.
Parameters in F01 to F03 as well as F10 are not displayed with the factory default setting.
Monitor Display Mode
[Figures on the SV display shows a “factory set value.”]
Event 2 set value (EV2) * Set value 1 (SV1)
SV1
$
0000
SV1
SV2
$
0000
SV1
SV3
$
0000
SV1
SV4
$
0000
SV1
Set value 2 (SV2)
Set value 3 (SV3)
Set value 4 (SV4)
SVT1
00:01
SV1
SVT2
00:01
SV1
SVT3
00:01
SV1
SVT4
00:01
SV1
SVRU
$
0000
SV1
SVRD
$
0000
SV1
TMF5
0000
SV1
RPT5
0000
SV1
EV1
$
0050
SV1
EV1`
$
-050
SV1
EV2
$
0050
SV1
EV2`
$
-050
SV1
EV3
$
0050
SV1
EV3`
$
-050
SV1
EV4
$
0050
SV1
EV4`
$
-050
SV1
S-SV
0001
SV1
ATU
0000
SV1
STU
0000
SV1
P
$
0030
SV1
I
0240
SV1
D
0060
SV1
ARW
%
0100
SV1
Pc
%
0100
SV1
DB
$
0000
SV1
F01
F01
F01
F01
SV selection
F01
Timer 1
F02
Timer 2
F02
Timer 3
F02
Timer 4
F02
Timer function
F02
Repeat execution times
F02
Setting change rate limiter (up)
F03
Setting change rate limiter (down)
F03
Event 1 set value (EV1) *
F04
Event 1 set value (EV1’)
[low]
F04
SET
Event 2 set value (EV2’)
[low]
Event 3 set value (EV3) *
Event 3 set value (EV3’)
[low]
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
F04
F04
F04
F04
Event 4 set value (EV4) *
F04
Event 4 set value (EV4’)
[low]
F04
utotuning (AT)
F05
Startup tuning (ST)
F05
Proportional band [heat-side]
F06
Integral time
F06
Derivative time
F06
nti-reset windup (ARW)
F06
Proportional band [cool-side]
F06
Overlap/Deadband
F06
Manual manipulated output
value (MV)
HBA1
0000
SV1
HBA2
0000
SV1
LBA
0480
SV1
Lbd
$
0000
SV1
T
0020
SV1
MT
0000
SV1
OLH
%
105.0
SV1
OLL
%
105
.
0
SV1
t
0020
SV1
Mt
0000
SV1
PB
$
0000
SV1
DF
0001
SV1
M-MV
%
000
.
0
SV1
SET
Heater break alarm 1
(HBA1) set value
Heater break alarm 2
(HBA2) set value
Control loop break alarm
(LBA) time
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
F07
F07
F07
LBA deadband (LBD)
F07
Proportional cycle time
[heat-side]
F08
Minimum ON/OFF time of
proportioning cycle [heat-side]
F08
Output limiter high
[Heat-side output limiter (high)]
F08
Output limiter low
[Cool-side output limiter (high)]
F08
Proportional cycle time
[cool-side]
F08
Minimum ON/OFF time of
proportioning cycle [cool-side]
F08
PV bias
F09
PV digital filter
F09
F10
SET
SET
Fine tuning setting
PTU
0000
SV1
F06
Return to first parameter setting item
* If any of the following Event functions are selected, this parameter will be Event set value (EV) [high].
(Event number at parameter setting shows up in .)
・Band (High/Low individual setting) [Event type code: U] ・Deviation high/low with hold action (High/Low individual setting) [Event type code: Y]
・Deviation high/low (High/Low individual setting) [Event type code: X] ・Deviation high/low with re-hold action (High/Low individual setting) [Event type code: Z]
(P. 8-14)
(P. 8-13)
(P. 8-13)
(P. 8-13)
(P. 8-13)
(P. 8-15)
(P. 8-15)
(P. 8-15)
(P. 8-15)
(P. 8-16)
(P. 8-17)
(P. 8-18)
(P. 8-18)
(P. 8-20)
(P. 8-22)
(P. 8-20)
(P. 8-20)
(P. 8-22)
(P. 8-20)
(P. 8-22)
(P. 8-22)
(P. 8-24)
(P. 8-25)
(P. 8-26)
(P. 8-26)
(P. 8-27)
(P. 8-27)
(P. 8-28)
(P. 8-29)
(P. 8-30)
(P. 8-36)
(P. 8-31)
(P. 8-31)
(P. 8-32)
(P. 8-34)
(P. 8-37)
(P. 8-38)
(P. 8-38)
(P. 8-39)
(P. 8-40)
(P. 8-41)
(P. 8-41)
(P. 8-42)
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
SET
(2 seconds or more)
SET