[SENSe]
. :FREQuency
. . [:CW|FIXed] <numeric_value>|UP|DOWN|MINimum|MAXimum
Setting of receiver frequency.
Parameters:
<numeric_value> frequency value
UP|DOWN increase|decrease of receiver frequency by the value set
in the command
SENS:FREQuency[:CW|FIX]:STEP[:INCRement]
MINimum|MAXimum setting the lowest|highest receiver frequency
Example:
FREQuency 101.2 MHz
[SENSe]
. :FREQuency
. . [CW|FIXed]? [MINimum|MAXimum]
Query of receiver frequency.
Parameters:
none query of current receiver frequency
MINimum|MAXimum query of lowest|highest receiver frequency
Result:
Frequency value in Hz
Example:
FREQuency? -> 101200000