R&S PR100 User Manual
[SENSe]
. :FREQuency
. . [:CW|FIXed]
. . . :STEP
. . . . [:INCRement] <numeric_value>| MINimum|MAXimum
Setting of receiver frequency.step size
Parameters:
<numeric_value> frequency value
MINimum|MAXimum setting the lowest|highest frequency step size
Example:
FREQuency:STEP 1 MHz
[SENSe]
. :FREQuency
. . [CW|FIXed]
. . . :STEP
. . . . [:INCRement]? [MINimum|MAXimum]
Query of receiver frequency.
Parameters:
none query of current frequency step size
MINimum|MAXimum query of lowest|highest frequency step size
Result:
Frequency value in Hz
Example:
FREQuency:STEP? -> 1000000