R&S PR100 User Manual
[SENSe]
. :FREQuency
. . :MODE CW|FIXed|SWEep|MSCan|PSCan
Changing the operating mode of the receiver.
Parameters:
CW | FIXed receiver monitors a frequency (CW and FIXed have equal
meanings)
SWEep receiver is in frequency-scan mode (see SENSe:SWEep)
MSCan receiver is in memory-scan mode (see SENSe:MSCan)
PSCan receiver is in panorama-scan mode (see SENSe:PSCan)
Remark:
The receiver stays on the CW frequency until it starts scanning.
Example:
FREQuency : MODE SWEep
[SENSe]
. :FREQuency
. . :MODE?
Query of receiver operating mode.
Parameters:
none
Result:
CW, SWE, MSC, PSC
Example:
FREQuency:MODE? -> SWE