R&S PR100 User Manual
[SENSe]
. :FREQuency
. . :PSCan
. . . :CENTer <numeric_value>|MINimum|MAXimum
Setting of center frequency of an RF-panorama scan. This command uses
“SENS:FREQ:PSC:SPAN?” to calculate new start and stop frequencies. It
thus changes SENS:FREQ:PSC:STAR and SENS:FREQ:PSC:STOP.
Parameters:
<numeric_value> center frequency
MINimum|MAXimum setting the lowest|highest center frequency
Example:
FREQuency:PSC:CENTer 127 MHz
[SENSe]
. :FREQuency
. . :PSCan
. . . :CENTer? [MINimum|MAXimum]
Query of center frequency of an RF-panorama scan.
Parameters:
none query of current center frequency
MINimum|MAXimum query of lowest|highest center frequency
Result:
Frequency in Hz
Example:
FREQuency:PSC:CENTer? -> 127000000