Management of the M-48 live personal mixer
Management of the M-48 live personal mixer
1.
Access the desired M-48 SETUP popup.
fig.ScrM48Setup.eps
2.
Press [F6 (PREF)].
fig.ScrM48Pref_Guide.eps
The M-48 PREFERENCES popup will appear.
3.
Make the desired preference settings.
Target unit indication
This indicates the M-48 that is the target of the M-48
PREFERENCES popup.
SOLO mode selection buttons
These buttons select the solo operation.
The solo modes and their operations are as follows:
LAYER select clears SOLO button
This specifies that when the layer is switched, the solo
settings of the now-hidden layer will automatically be
cleared.
MEMORY operation select buttons
These buttons restrict memory operations performed from
the M-48’s panel.
LINE OUT SOURCE select buttons
These buttons select one of the following as the LINE OUT
source:
You’ll need to exercise due caution in order to prevent
feedback if you select “PHONES,” since the signal from the
ambient microphone will also be included in the output.
LINE OUT LPF (Low-pass filter)
This is the LPF setting for the line out.
Note that the level of the output from Line Out will change
significantly if you switch the LPF from a setting of “80 Hz” or
“120 Hz” to “OFF.” Be sure to exercise due caution so that the
signal sent to the equipment connected to Line Out, or to
your ears, is not at an excessively high level.
The LPF is a 12 dB/oct filter that passes the region below the
specified frequency.
LINE OUT MODE select button
If the MONO button is checked, a monaural mix will be
output from the line out.
1.
Access the desired M-48 SETUP popup.
2.
Press [F6 (PREF)].
fig.ScrM48Pref.eps
The M-48 PREFERENCES popup will appear.
Making preference settings for an M-48
unit
ADD ON
Multiple groups can be soloed. Soloed groups
will be mixed for monitoring.
LAST Only the last soloed group will be monitored.
Disable RECALL
button
If this is checked, the [RECALL] button will be
disabled.
Disable STORE
button
If this is checked, the [STORE] button will be
disabled.
2
1
3
4
5 6 7
1
2
3
4
MAIN BUS
Output the signal of the MAIN BUS.
AUX BUS Output the signal of the AUX bus (the mix of the
sources whose AUX switch is turned on in the
source level/pan settings, p. 178).
PHONES Output the signal from before the PHONES
VOLUME.
OFF The LPF will not be used.
80 Hz The frequency region below 80 Hz will be passed.
120 Hz The frequency region below 120 Hz will be
passed.
Returning the preference settings to the
default state