2.7 Requirements for commissioning the machine
Work on the electrical equipment of the machine, particularly profes-
sional installation of the mains plug, may only be carried out by quali-
fied personnel who are familiar with the safety instructions.
The maximum permitted fuse of the mains is specified in the enclosed
electro circuit diagram or on the sign “Electrical connected loads”.
The machine may only be connected to the electric power supply with
the mains plug! No permanent installation, e.g. by means of screw
clamps, is permitted. The mains plug is used as a disconnecting de-
vice, and must always be clearly visible and easily accessible.
Measure the alternating field direction. Swap two phases on the mains
plug if necessary.
The line filter generates static and dynamic leakage currents. These
can lead to unwanted tripping of the residual current device when in-
serting the mains plug or switching on and operating the machine.
Please note that on machines with a line filter, smooth DC residual
currents or leakage currents can arise, which are not reliably detected
by type A residual current devices. Type A residual current devices are
therefore not permitted.
Please contact an electrical specialist to ensure correct selection of the
residual current device and adhere to the local regulations.
Note
• Three-phase electronic equipment with plug connections ≤ 32 A may
only be operated via AC/DC-sensitive residual current devices with IΔn
≤ 30 mA or protective isolating transformers.
• Three-phase electronic equipment with plug connections > 32 A to 63
A may only be operated via AC/DC-sensitive residual current devices
with IΔn ≤ 500 mA or protective isolating transformers.
• Three-phase electronic equipment with plug connections > 63 A may
only be operated via AC/DC-sensitive residual current devices or pro-
tective isolating transformers.