EasyManua.ls Logo

Samsung DCS-816 - MMC: 501 SYSTEM-WIDE TIMERS

Samsung DCS-816
313 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SAMSUNG Programming
DCS-816 February, 1999
MMC 501 (Page 1 of 7)
MMC: 501 SYSTEMWIDE TIMERS
DESCRIPTION:
Allows the technician to adjust individual timers as necessary. Any timer can be
disabled by setting the time to all zeros (000).
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
ACTION DISPLAY
1. Press TRSF 501
Display shows first timer value
AA INT DGT TIME
05 SEC
2. Press UP or DOWN key to select timer and press
RIGHT soft key to move cursor
KMMC LOCK OUT TM
30 SEC
_
3. Enter new value using keypad; if valid, system
returns to step 2 with new value
KMMC LOCK OUT TM
30 SEC
255
4. Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: See table of timers and values, below
RELATED ITEMS: None

Table of Contents

Other manuals for Samsung DCS-816

Related product manuals