SAMSUNG Programming
DCS-816 February, 1999
MMC 219 (Page 1 of 1)
MMC: 219
COMMON RELAY SERVICE TYPE
DESCRIPTION:
This MMC is used to define the function of the common relay in the base board.
The relay can be used for one of the following:
0 EXTERNAL PAGE
1 COMMON BELL
2 LOUD BELL
3 NOT USE
ACTION DISPLAY
1. Press TRSF 219
Display shows
[362] RELAY TYPE
NOT USE
2. Use UP or DOWN to scroll through
options.
[362] RELAY TYPE
COMMON BELL
[362] RELAY TYPE
LOUD BELL
[362] RELAY TYPE
EXTERNAL PAGE
3. Press TRSF to store and exit
OR
Press SPK to store and advance to next
MMC
DEFAULT DATA: External Page
RELATED ITEMS: MMC 203 Assign UA Device
MMC 204 Common Bell Control
MMC 205 Assign Loud Bell