MMC: 503 TRUNK–WIDE TIMERS
DESCRIPTION:
Allows certain trunk timer values to be changed on a per–trunk basis or for all
trunks. It is not advisable to change these values (with the exception of trunk flash
time) without assistance from Technical Support.
DIAL TIMER RANGE
0 ANS.BAK TM 100–2500 MSEC
1 CLEARING 01–25 SEC
2 CO SUPV TM 100–2500 MSEC
3 DTMF DUR. 100–2500 MSEC
4 F–DGT DELY 100–2500 MSEC
5 FLASH TIME 100–2500 MSEC
6 NO RING TM 001–255 SEC
7 PAUSE TIME 001–255 SEC
8 PRS DET TM 000–2500 MSEC
9 RNG DET.TM 100–2500 MSEC
10 WINK TIME 100–300 MSEC
11 MF/DP INT 100–9900 MSEC
12 MFR DLY TM 00–25 SEC
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
ANS/RLS Used to select ALL
ACTION DISPLAY
1. Press TRSF 503
Display shows
[701] ANS.BAK TM
0600 MS
→
2. Dial trunk number (e.g., 704)
OR
Press UP or DOWN key to select trunk and
press RIGHT soft key to move cursor
OR
Press ANS/RLS to select all trunks and press
RIGHT soft key to move cursor
[704] ANS.BAK TM
0600 MS
→
[ALL] ANS.BAK TM
0600 MS
→
3. Dial timer number from above list
OR
Press UP or DOWN key to select timer and press
RIGHT soft key to move cursor
[704] DTMF DUR.
0600 MS
→
_