7. EXPLANATION OF PARAMETERS
760
Mode Page
Abbre-
viation
Name and description Standard value
Setting
range
Remarks
4 8 PSKD Power supply type
Selects the type of power supply for the servo
amplifier’s main power supply circuit.
Selectable power supplies differ depending
on the amplifier series.
PY2A series (200 VAC input type)
200 VAC, 3ph (200 VAC, 3-phase)
200 VAC, 1ph (200 VAC, single-phase)
PY2E series (100 VAC input type)
Only 100 VAC, 1ph (100 VAC,
single-phase) can be used, and changing
to another power supply is impossible.
In the case of special motors (motor code: FF),
the type of power supply cannot be selected.
Motor codes are indicated on the initial screen.
(Refer to 7.1.3 Basic Operating Procedure.)
$$$$ 2 types
1 type
PY2Axxx
PY2Exxx
9 RGKD Regenerative resistor type
Selecting regenerative resistor to use.
Selectable Motor differs according to Servo
Amplifier capacity.
None/ Ext.R : Regenerative resistor is not
connected, or external
regenerative resistor.
Built-in R : Built-in regenerative resistor
Refer to 9.5 Built-in Regenerative resistor
(Built-in R) for detail of parameter setting on
regenerative resistor.
$$$$ : The standard value varies according to
the specifications employed at the time
of shipping.
$$$$ 2 types
Note the following for changes to be conducted on Pages 3 to 6 and 8 (system parameters):
1 Turn off the control power before change.
2 Change is effective only after Func6 bit7 is set at "1" from Screen Mode 2.
3 If the above operation (Func6 bit7 to "1") is ignored, the parameter change is invalid
and, thus, the change does not take place.
Page 7 (motor configuration) is for reference only and cannot be edited or changed.
When using regenerative resistor built-in the Servo Amplifier, make sure to set
regenerative resistor type (RGKD) on page 9 to “built-in regenerative resistor (built-in R)”.
With this parameter setting, enable/ disable of built-in regenerative resistor overheat
protection detection processor is judged. In case that “regenerative resistor is not
connected or external regenerative resistor (None/ Ext.R)” is selected, overheat detection
of built-in regenerative resistor will not be executed. Consequently, built-in regenerative
resistor may be burn or smoke occurs.