13.1.3 Clearing
In partitions [Msg.abort in P.]
For each telephone, you can indicate partitions in which clearing an alarm will cancel
messaging that alarm (messaging to that telephone number will be canceled, but can be
continued to other numbers).
After acknowledgement [Msg.abort on T.]
You can indicate telephones which will not be notified about the event, if the control panel
receives acknowledgement that the voice message has been received by another, indicated
telephone.
13.1.4 Pager messages / SMS
Define the content of messages which will be used for PAGER or SMS type messaging.
13.1.5 Pager type
For messaging using the PAGER type messages, you must define the parameters of pager
identification. Default parameters of the pager type 1 are adjusted to the SATEL GSM
module requirements for conversion of the PAGER type message into SMS message.
13.2 Starting the voice messaging
1. Enable the TELEPHONE MESSAGING option.
2. Using the telephone options (see: Telephone options” p. 71):
define the mode of dialing the telephone numbers (TONE DIALING option and in case of
the pulse dialing – PULSE DIALING 1/1.5 (OFF 1/2) option),
determine whether the control panel, prior to dialing the number, should check the
telephone line for dialing signal (NO DIAL TONE TEST option),
determine whether the control panel is to play back the voice message after going off-
hook, or 15 seconds after the dialing is completed (global option NO ANSWER TEST).
determine whether the voice message is to be played back once or twice (option
DOUBLE VOICE MESSAGE).
3. Define the number of attempts to get connected in one round (function MAX. REDIAL
NUMBER FOR ONE ROUND
).
4. Define parameters of the telephones to which messages are to be sent:
name (up to 16 characters),
telephone number,
type of messaging (select 0 – voice),
number of attempts made by the control panel to notify the indicated telephone
number about the event, if receipt of the message has not been acknowledged,
how the receipt of voice message is to be acknowledged (if the messaging is to be
acknowledged, enable the ANY CODE option or enter the 4-digit code).
5. Record or synthesize the voice messages which are to be used for messaging (see:
CA-64 SM synthesizer or INT-VG voice module manual).
6. For events about which the control panel is to inform, indicate:
number of the voice message to be used for messaging,
telephones to be notified.
7. In order to limit unnecessary messaging, define the cases in which notification can be
cancelled (the parameters CLEARING IN PARTITIONS and CLEARING AFTER ACKNOWLEDGEMENT
and the option CLEAR MESSAGING ON ALARM CLEARING).