50 Programming SATEL
Disarm by two codes [2 cds to d-arm] – if this option is enabled, disarming requires that
codes be entered in turn by two users.
Codes on two keypads [Codes on 2 kpd] – if this option is enabled and the partition is
armed/disarmed using two codes, they must be entered from different keypads.
Valid within 60 sec [1st code 60s] – if this option is enabled and two codes are required for
arming/disarming, the second user has to enter the code within 60 seconds of entering the
code by the first user.
Timer priority – if this option is enabled, arming/disarming is always done by the timer. If this
option is disabled, the timer will disarm the partition if it was armed by the timer (if it was
armed by the user, the timer will not disarm the partition).
Infinite exit delay [Infin.ex.delay] – if this option is enabled, the partition will be armed after
entering the code and then:
– violating the 86. ENTRY/EXIT – FINAL, 87. EXIT – FINAL or 89. FINISHING EXIT DELAY type
zone,
– shortening of the exit delay time by the user (see EXIT DELAY CLEARING option).
If partition is not armed within 260 seconds, the “Arming failed” event will be registered to
the control panel memory. With the option enabled, the P
ARTITION EXIT DELAY will be taken
into account, if the partition is armed using a zone or timer.
Exit delay clearing [Fin.exit delay] – if this option is enabled, you can reduce the exit delay
countdown by entering 9
from the keypad/partition keypad. The partition will be armed
immediately. The exit delay clearing is only available from the same keypad/partition
keypad, from which the partition was armed (the EXIT DELAY CLEARING ENABLE option must
be enabled in the keypad).
Default block time – the option applies to the WITH TEMPORARY BLOCKING partition type. If the
option is enabled and the DEFAULT PART. BLOCK TIME is preset, the partition will be blocked
on arming for a default time period, as defined by the installer (the blocking time cannot be
programmed by the user).
Alarm – disarm allowed – the option applies to the WITH TEMPORARY BLOCK partition type.
During alarm, the partition can be disarmed by the users who do not have the ACCESS TO
TEMPORARY BLOCKED PARTITIONS
right.
Audible alarm after verification [Bell on 2nd] – if this option is enabled, the alarms from
zones with the PRE-ALARM or WITH VERIFICATION option enabled will only trigger loud alarm
signaling after verification. The unverified alarms will not trigger loud alarm signaling.
Partition timer
Partitions can be controlled with an additional timer, which can be programmed:
• in the keypad, using the function available in the user menu ([code] OPTIONS
PROGRAMMING
PARTITION TIMERS),
• in the DLOADX program connected to the control panel, in the “Structure” window,
“System” tab, after clicking on the partition name and then on the “Partition timer” button.
4.3 Zones
The zone is a separated portion of the protected area which can be supervised by a detector
or detectors. A zone can only be assigned to one partition.
The system supports the following zones:
• hardwired – on the control panel electronics board, in keypads and expanders.
The number of available hardwired zones is determined by the control panel during
identification procedure.