68 Programming SATEL
5.4 Output triggering
Zones – indicate the zones. The output will be controlled by events related to these zones.
LCD keypads – indicate the LCD keypads. The output will be controlled by events related to
these LCD keypads.
Partitions – indicate the partitions/partition keypads. The output will be controlled by events
related to these partitions/partition keypads.
Timers – indicate the timers which will control the output.
Master users / users – indicate the masters/users. The output will be controlled by events
related to these masters/users.
Outputs – indicate the output. The output will be controlled by events related to these
outputs.
Expanders – indicate the expanders. The output will be controlled by events related to these
expanders.
Troubles – indicate the troubles. The output will be activated by occurrence of these
troubles.
Voice mess. – indicate the synthesizers. The output will be active when the voice messages
with indicated numbers are played back.
Remote switches – indicate the remote switches. The users will control the output by
controlling the selected switches via the telephone.
Burglary zones in partition – indicate the partition in which the output will be activated by
starting the test of burglary zones.
Fire/technical zones in partition – indicate the partition in which the output will be activated
by starting the test of fire or technical zones.
Arm mode – indicate the arm mode whose activation will activate the output.
Telephone usage type – indicate which cases of using the telephone communication by the
alarm control panel will activate the output.
5.5 Clearing alarm in partitions
Indicate the partitions in which alarm clearing will be available (the users having access to
these partitions will be able to clear the alarm).
The alarm must be signaled in the partition where it is to be cleared. If no alarm is
being signaled by the given partition, it will be impossible to clear it.
5.6 Output disabling
Disabling timers – for the 105. SHUTTER UP and 106. SHUTTER DOWN type outputs, you can
indicate the timers which will block the output. When the timer is active, disarming
(105. SHUTTER UP) / arming (106. SHUTTER DOWN) will not activate the output.
Partitions – for the 11. CHIME type output, you can indicate the partitions from which the user
will be able to block the output using the OUTPUTS CHIME function.
5.7 120. Thermostat output settings
The 120 Thermostat type output settings are used to adjust the operating parameters
of the ART-200 wireless radiator thermostats.
Temperature detector – zones used to provide data on temperature. Data on temperature
can be received from ABAX 2 wireless devices provided with temperature sensors. The
devices must be assigned to these zones.