SATEL INTEGRA 57
85. ENTRY/EXIT – CONDITIONAL – similarly as the 0. ENTRY/EXIT type with an extra feature: the
zone becomes an instant one upon arming, if no partition exit is registered upon starting
the arming procedure.
86. ENTRY/EXIT – FINAL – similarly as the 0. ENTRY/EXIT, but the zone restore during exit delay
countdown will terminate the exit delay countdown and arm the system.
87. EXIT – FINAL – similarly as the 6. EXIT, but the zone restore during exit delay countdown
will terminate the exit delay countdown and arm the system.
88. 24H BURGLARY – a permanently armed zone. Its violation will cause the burglary alarm.
89. FINISHING EXIT DELAY – zone violation will reduce the partition exit delay time. It is possible
to program a shorter exit delay time. If this value remains not programmed, the exit delay
will be reduced to 4 seconds from the zone violation. There will be no effect if the zone is
violated and the just running exit delay is shorter than that programmed for the zone.
90. DISABLING VERIFICATION – zone violation will disable verification of alarms in the partition.
All alarms will be unverified until next arming.
91. DETECTOR MASK – the permanently armed zone, dedicated to anti-masking control.
Violation of the zone will be treated by the control panel as detector trouble (masking).
92. O
UTPUTS GROUP OFF – the zone allows to deactivate a selected group of outputs.
93. O
UTPUTS GROUP ON – the zone allows to activate a selected group of outputs.
94. ENTRY/EXIT INTERIOR – similarly as the 0. ENTRY/EXIT, but it will only be armed in the case
of full armed status (arming modes 0 and 1).
95. ENTRY INTERIOR – similarly as the 1. ENTRY, but it will only be armed in the case of full
armed status (arming modes 0 and 1).
96. FIRE MONITORING – permanently armed zone. After the zone is violated, fire alarm
information is saved to the control panel memory.
97. FIRE PANEL FAULT. MONIT. – permanently armed zone. After the zone is violated, an event
is saved to the control panel memory.
4.3.6 Zone options
Power up delay – when the option is enabled, the zone will be bypassed for 120 sec. after
power-up (which prevents triggering alarms e.g. when starting the alarm control panel).
Priority – when this option is enabled, arming will be impossible, if the zone is violated (e.g.
windows have been left open, etc.).
Contr. by pulse(off-by state) – option for 82. ARM/DISARM zone type. If it is enabled,
violation of the zone will arm/disarm the partition (depending on the current status of the
partition). If the option is disabled, zone violation will arm, and the zone restore will disarm
the partition.
CHIME in module – with this option enabled, zone violation can be signaled in partition
keypads, code locks and readers expanders assigned to the same partition as the zone
(the option CHIME must be enabled in the expander).
No alarm sign. in keypad – option for 13. PANIC-SILENT zone type. If it is enabled, alarm from
this zone will not be signaled on keypads. Clearing this alarm by means of keypad will not
be possible.
Outputs signaling the silent panic alarm can be deactivated using the CLEAR LATCHED
OUTPUTS user function.
Video on disarmed – if this option is enabled, violating the zone when the partition is
disarmed will activate the 15. VIDEO ON DISARMED type output.
Video on armed – if this option is enabled, violating the zone when the partition is armed will
activate the 16. VIDEO ON ARMED type output.
Bypass disabled – if this option is enabled, the user cannot bypass the zone.