58 Programming SATEL
Bypassed if no exit if this option is enabled, the zone will be automatically bypassed,
when no partition exit is registered during the partition exit delay countdown. The zone will
also be bypassed when the full + bypassesarming mode is on (registering a partition exit
is irrelevant then). The zone will be unbypassed after the partition is disarmed.
Alarm in arm state an option for the zone types 64-79. It is available, if the NO BYPASS IF
ARMED
option is enabled. When it is enabled, violating an armed zone will cause an alarm
(if the partition exit was registered upon arming).
Alarming option available for the 91. DETECTOR MASK zone type. If enabled, violation of the
zone will additionally trigger an alarm.
Auto-reset 3 with this option enabled, the zone can trigger up to 3 alarms. As long as the
alarm is not cleared or the partition is not armed/disarmed, violations of the zone will not
trigger any alarm.
Auto-reset 1 with this option enabled, the zone can trigger only 1 alarm. As long as the
alarm is not cleared or the partition is not armed/disarmed, violations of the zone will not
trigger any alarm.
Clearing Autoreset with this option enabled, alarm counters for the zones for which the
A
UTO-RESET 3 or AUTO-RESET 1 option is enabled can be automatically reset at midnight
(violations of these zones will be able to trigger alarms again).
Pre-alarm if this option is enabled, alarms from the zone will be verified.
With verification an option for the zone types 0-2, 85-86 and 94-95. If it is enabled, alarms
from the zone will be verified.
Alarm from the zone with enabled P
RE-ALARM or WITH VERIFICATION option will be an
unverified alarm, unless during verification (see description of the ALARM VERIFICATION
TIME parameter p. 49) an alarm will be caused by another zone with enabled PRE-
ALARM or WITH VERIFICATION option. In such a case, a verified alarm will be triggered.
Bell delay an option for the zone types 5 and 6. It changes the way of reaction to a zone
violation when armed. If the option is disabled, the alarm from zone will be delayed by
a programmed time period (ALARM DELAY). If the option is enabled, the zone will alarm
immediately (event, reporting and telephone messaging), but the loud signaling will be
delayed by a programmed time period (SIGNALING DELAY).
Delay in 2&3 type arming an option for the 3. INTERIOR DELAYED zone type. If the option is
enabled, the zone will be armed and act as a delayed one upon activation of the type 2
(without interior) and type 3 (without interior and without entry delay) arm mode.
Alarm clearing an option for the zone types 81 and 82. With this option enabled, violation
of the zone will clear alarm in the partition, if it is currently indicated.
Abort delay when this option is enabled, violating the zone during the entry delay
countdown will result in registering a Zone violation event (this event can only be
reported in the 4/2 format). When the option is disabled, violating the zone during the entry
delay countdown will result in registering an Alarm event (this event is reported and
initiates messaging).
Report if not armed option for the 7. DAY/NIGHT zone type. If it is enabled, the alarm will
be reported at all times. If it is disabled, the alarm will only be reported if the zone is
armed. If the zone is disarmed, the zone violation will trigger a warning alarm. The warning
alarm does not cause any loud alarm signal and is not reported. It can be signaled by the
9. DAY ALARM, 12. SILENT ALARM and 116. INTERNAL SIREN type outputs.
Event: arming failed [Event arm fail] option for 80. ARMING and 82. ARM/DISARM zone
types. If this option is enabled, unsuccessful arming by means of zone is saved to the
event log.
Partition temporary blockingoption for the 84. GUARD zone type. If it is enabled, violation
of the zone will block the partition for the time of guard round.