SATEL INTEGRA 69
Temperature T1 the first temperature threshold (economic temperature). It is active when
all control timers are OFF or the forcing output is active. If the first temperature threshold is
active, the output will be turned on when the temperature drops below temperature T1
(economic temperature).
Temperature T2 the second temperature threshold (comfortable temperature). It is active
when the control timer is ON or the forcing output is inactive. If the second temperature
threshold is active, the output will be turned on when the temperature drops below
temperature T2 (comfortable temperature).
Hysteresis temperature difference between turning the output on and off. The output will
be turned on when temperature drops below the threshold by a value higher than the
hysteresis. The output will be turned off when temperature reaches the threshold.
Hysteresis is used to eliminate the undesirable output state changes when temperature
fluctuations occur.
The user can edit the temperature thresholds and hysteresis using the TEMPERATURES
user function available in the CHANGE OPTIONS submenu.
Output forcing T1 output that forces temperature T1 to be active. If the output is turned
on, the first temperature threshold (economic temperature) will be active. If the output is
turned off, the temperature thresholds will be controlled by timers. If the forcing output is
not selected, the temperature thresholds will only be controlled by timers.
Timers controlling T1/T2 timers used to control the temperature thresholds. If the timer is
turned on, the second temperature threshold will be active (unless the forcing output is
turned on).
Timers set if this option is enabled, the output can be controlled by timers 33-64. If this
option is disabled by timers 1-32.
The user can edit the parameters of control timers using the TIMERS user function
available in the CHANGE OPTIONS submenu.
Edition in ART-200 if this option is enabled, the keys on the ART-200 wireless radiator
thermostat will be enabled. This means they can be used to:
change the operating mode (when the operating mode is changed manually, the
thermostat will not use the active temperature threshold of the thermostatic output),
change the temperature threshold settings (when the settings are changed in the
thermostat, the thermostatic output settings will also be changed),
start other functions available in the thermostat.
If this option is disabled, the keys on the ART-200 thermostat will be disabled.
5.7.1 Rules for programming the thermostatic output settings
Temperature programming rules
You can enter a value from -30°C to 70°C (with accuracy to 0.).
The ART-200 wireless radiator thermostat regulates temperature in the range from
C to 30°C.
Hysteresis programming rules
You can enter a value from 0°C to 7.C (with accuracy to 0.). If you program 0°C, the
thermostat will be turned on when the temperature drops below the threshold by 0.C.
5.8 Output groups
The outputs of MONO SWITCH, BI SWITCH, REMOTE SWITCH, SHUTTER UP and SHUTTER DOWN
type can be grouped by the function performed by them. Each group may be given a name.