SATEL INTEGRA 95
Exception the period during which the timer will be started/ended at a different time. 4
exceptions can be programmed for a timer. You can program for each exception:
the date from which the exception will apply,
the date to which the exception will apply,
the timer start/end time when an exception applies.
If a year is programmed for an exception, the setting will only be valid for the current
year. If no year is programmed (the 9999 sequence is entered in the keypad instead of
the year), the exception will be valid every year.
Arming mode the arming mode which will be activated when the timer starts (in the
DLOADX program, enter an additional digit next to the timer start time: 0 full arming; 1
full arming + bypasses; 2 arming without interior; 3 arming without interior and without
entry delay).
11. User schedules
User schedules should be defined for the needs of the SCHEDULE type users (see: USER
MANUAL
). You can program the user schedules:
using the keypad, in the service mode, by means of the functions available in the USER
SCHEDULES
submenu,
using the DLOADX program, in the Timerswindow, User Schedulestab.
For each user schedule, you can:
program an individual name (up to 16 characters),
indicate the timers which will determine when the user will have access to the system.
12. Reporting
The control panel can send event codes to the monitoring station using the following
transmission paths:
analog telephone line (INTEGRA 128, INTEGRA 64, INTEGRA 32 or INTEGRA 24 control
panel),
GSM voice channel (INTEGRA 128-WRL control panel) the use of this transmission path
is not recommended because of distortions that may occur when sending the event codes,
Ethernet (connection of the ETHM-1 Plus / ETHM-1 module to the control panel required),
cellular data network (INTEGRA 128-WRL control panel; in case of other control panel
INT-GSM / INT-GSM LTE module must be installed in the alarm system or SATEL GSM
module must be connected to the control panel),
SMS (INTEGRA 128-WRL control panel; in case of other control panel INT-GSM /
INT-GSM LTE module is required to be installed in the alarm system) the control panel
gets no acknowledgement of event code receipt.
The control panel will try to send event code to the monitoring station using in turn:
1. ETHM-1 Plus / ETHM-1 module and/or INT-GSM / INT-GSM LTE module. If several such
modules are connected to the control panel, that with the lowest address will be used.
Event code can be sent via Ethernet, cellular data network or SMS.
When configuring the ETHM-1 Plus module to which the INT-GSM / INT-GSM LTE
module is connected, or when configuring the INT-GSM / INT-GSM LTE module
connected directly to the control panel, define priority of the transmission paths. The
transmission path which is not included in the list defining the priority of transmission
paths, will not be used.