SATEL INTEGRA 77
6.5 Times
Global entry delay – parameter taken into account in the delayed zones, for which the
programmed ENTRY DELAY is equal to 0.
Global alarm time – time of signaling alarm in keypads, proximity card arm/disarm devices,
proximity card readers and DALLAS chip readers.
No armed indication after – time counted from the moment of partition arming, during which
information about armed status is displayed on the keypads. Programming the value 0
means that keypads will indicate the armed status as long as the partition is armed.
AC loss report delay – time during which the control panel must not receive AC power so
that information of it can be saved to the event log. Having programmed the value 0
means that the information of AC power loss will not be saved to the event log.
Tel. line loss report delay – time during which abnormal voltage must be on the telephone
line for the control panel to report the telephone line trouble. This delay prevents the
reporting of short-time voltage dips (e.g. during a phone call) or decays. If you enter 0, the
control panel will not report the telephone line trouble.
Default part. block time – the time period during which the W
ITH TEMPORARY BLOCK type
partitions with enabled D
EFAULT BLOCK TIME option will be blocked.
Summer/winter time [Daylight saving] – the control panel can automatically adjust the clock
settings due to a change from the summer time to the winter time according to the
selected schedule.
Summer time from – if the control panel clock is to be corrected by 1 or 2 hours according to
dates, you should enter the dates (day, month) after the clock is changed to the summer
time (moved forward).
Winter time from – if the control panel clock is to be corrected by 1 or 2 hours according to
dates, you should enter the dates (day, month) after the clock is changed to the winter
time (moved back).
RTC clock correction [Clock adjustm.] – if the accuracy of control panel clock is inadequate,
the clock settings may be adjusted once per 24 hours (at midnight) by a defined time. The
correction time is programmed in seconds. The maximum correction can be ±19 seconds
per 24 hours.
Time server – if the control panel is to synchronize the time with the server (automatically
and after suitable function is enabled by the installer or master user), enter the address of
time server supporting the NTP protocol. Time synchronization is possible for the
INTEGRA 128-WRL control panel and any other panel to which the ETHM-1 /
ETHM-1 Plus / INT-GSM / INT-GSM LTE module is connected.
Time zone – if the control panel is to synchronize the time with the server, indicate the time
zone, i.e. the difference between the universal time (GMT) and the zone time.
Do not report time server connection trouble [No t.serv.trbl] – with this option enabled, no
trouble will be reported if there is no communication with the time server.
6.6 Service options and parameters
In the keypad, most of the options and parameters, as described below, are available in SM
SETTINGS
submenu.
Service access code – a code that allows access to the service mode, as well as some
functions in the user menu.
Disable service mode [Block SM] – with this option enabled, entering the service mode
“from pins” (by hardware means) will be impossible (entering the service mode “from pins”
will only be possible if the control panel factory settings are restored).