Access according to timer – the partition can be armed/disarmed by the user, but only
within the time intervals set by the indicated timers. The number of timers depends on the
control panel.
Controlled by timer – the partition, which is armed in time periods determined by selected
timers, but may also be controlled by the user code. The number of timers depends on the
control panel.
Bank vault – the partition can be armed / disarmed by the user. Disarming may be delayed
by a defined period of time (see: DISARM DELAY). After it has been disarmed, the partition
can be automatically re-armed after a defined period of time elapses (see: TIME TO RE-
ARM).
Times
Partition exit delay – the time counted from the start of the procedure of arming (by the
user, timer, zone, etc.), which allows to leave the protected area without triggering an
alarm.
Auto-arming delay [Auto-arm delay] – the time counted before starting the procedure of
arming by timer. It allows the user to postpone or cancel the auto-arming.
Alarm verification time [Al. verify time] – the time counted from the triggering alarm by
a zone included in alarm verification (with enabled PRE-ALARM or WITH VERIFICATION
option). If during the count another zone included in the alarm verification triggers an
alarm, a verified alarm will be triggered.
Guard round (on armed) every [Guard - armed] – the maximum period of time that can
elapse since the last guard round when the partition is armed. If the time is exceeded,
information about the lack of guard round will be saved to the control panel memory.
Programming the value 0 will disable the control of guard round.
Guard round (on disarmed) every [Guard - disarm.] – the maximum period of time that can
elapse since the last guard round when the partition is disarmed. If the time is exceeded,
information about the lack of guard round will be saved to the control panel memory.
Programming the value 0 will disable the control of guard round.
Blocked for guard round [Time for guard] – the time counted from the moment of
registering the guard round, during which the partition is blocked.
Cash machine block delay [C.mach.blk.del.] – the time counted from the moment of
entering the user code of the CASH MACHINE ZONES BYPASSING type. After expiry of this time,
the 24H CASH MACHINE type zones will be bypassed.
Cash machine block time [C.mach.blk.time] – the time during which the 24H CASH MACHINE
type zones will be bypassed after entering the user code of the CASH MACHINE ZONES
BYPASSING
type. The bypass can be delayed by the CASH MACHINE BLOCK DELAY.
Disarm delay – the parameter applies to the BANK VAULT partition type. The partition will only
be disarmed after a defined period of time has elapsed since the code was used by the
user. If the time is equal to 0, the partition will be disarmed immediately.
Time to re-arm – the parameter applies to the BANK VAULT partition type. After disarming, the
control panel will be analyzing for a defined period of time whether a door in the partition
will be opened by means of an access control module (partition keypad, code lock, etc.). If
the door is not opened, the partition will be automatically re-armed (the partition exit delay
countdown will not be running). If the time value is equal to 0, the partition will not be re-
armed. Irrespective of the preset value, if the DISARM DELAY parameter is 0, the partition
will not be re-armed.
Options
Arm by two codes [2 cds to arm] – if this option is enabled, arming requires that codes be
entered in turn by two users.