SATEL INTEGRA 59
Restore after bell – with this option enabled, the zone restore code will be reported to the
central monitoring station only after the alarm signaling is ended.
Restore after disarm – with this option enabled, the zone restore code will be reported to
the central monitoring station only after disarming the partition to which the zone belongs.
Alarm on exit delay end – with this option enabled, the zone will trigger alarm if it is violated
at the moment of ending the exit delay countdown. If the option is disabled, the alarm will
only be triggered in case of changing the zone status from normal to violated when armed.
Store to event log – option for the 47. NO ALARM ACTION and 63. TROUBLE zone types. If it is
enabled, violation of the zone will result in storing an event according to the zone type (in
case of the 47. NO ALARM ACTION zone type, the information to be written depends
additionally on the NO REPORTING option).
No reporting – option for the 47. NO ALARM ACTION zone type with the STORE TO EVENT LOG
option enabled:
– enabled – violation of the zone will write an event informing about zone violation,
– disabled – violation of the zone will result in writing an event informing about keybox
opening, the code of which is sent to the monitoring station.
No restore event – option for the 47. N
O ALARM ACTION zone type with STORE TO EVENT LOG
and N
O REPORTING options enabled. If it is enabled, the zone restore is not stored into the
event log.
Store event only if armed – option for the 47. NO ALARM ACTION zone type. It is available, if
the STORE TO EVENT LOG option is enabled. If it is enabled, violations of the zone will be
written into the event log, provided that the partition to which the zone is assigned, is
armed.
No bypass if armed – option for the 64-79 zone types. If it is enabled, violation of the armed
zone will block no group of zones (provided that during the exit delay countdown an exit
from the partition is recorded).
Messaging cancelling – option for the 81-83 zone types. If it is enabled, violation of the
zone will cancel the messaging, if it is currently ongoing.
Alarm on unbypass – if the option is enabled and the armed zone is violated after being
bypassed, an alarm will be triggered.
Tamper alarm always loud – if this option is enabled, tamper alarm is always loud (if option
is disabled – tamper alarm is loud only when armed).
Reporting delay – option for the 4-8 and 64-79 zone types. Violation of the zone during the
entry delay countdown will trigger a warning alarm. The warning alarm does not cause any
loud alarm signal and is not reported. It can be signaled by the outputs of 9. DAY ALARM,
12. SILENT ALARM and 116. INTERNAL SIREN type. If the zone is not disarmed within 30
seconds, the entry delay has expired or another instant is violated, the burglary alarm will
be triggered.
Blocks verification – option for 0-2, 85-86 and 94-95 zone types. If it is enabled, violation of
the zone will block verification of alarms in the partition. All alarms will be unverified until
the partition is armed again.
Check arm possibility – option for the arming zones (80 and 82 zone types). The zone will
not arm, if a zone with enabled PRIORITY option is violated in the partition, or other
circumstance have occurred which prevent arming (depending on the selected options,
tamper, trouble, etc.).
Restore disarms – option for the 89. FINISHING EXIT DELAY zone type. If it is enabled, the
zone restore will disarm the partition. This option overrides the option RESTORE DISABLES
VERIF
.