SATEL INTEGRA 63
9. DAY ALARM signals the following:
alarms from 13. PANIC-SILENT type zones,
medical alarms from the 14. MEDICAL - BUTTON and 15. PERSONAL EMERGENCY type
zones,
alarms from 7. DAY/NIGHT type zones, if the partition to which the zone belongs is
disarmed,
alarms from 8. EXTERIOR type zones, if the armed mode which assumes that the user
will stay inside the protected facility is enabled in the partition (see: USER MANUAL),
alarms from 4. PERIMETER type zones, if the SIGNALING DELAY has been programmed for
them,
alarm from 5. INSTANT and 6. EXIT type zones, if the BELL DELAY option has been
enabled and the SIGNALING DELAY has been programmed for them,
alarms from zones, for which the REPORTING DELAY option has been enabled, provided
they were violated during the ENTRY DELAY countdown,
unverified alarms, if the AUDIBLE ALARM AFTER VERIFICATION option is enabled for the
partition,
the first violation of the 8.
EXTERIOR type zones when they are armed, provided the
S
URVEILLANCE TIME has been programmed for the zone,
violation of the counting zones (16-31 type zones) when armed.
10. DURESS ALARM action carried out under duress signals that a DURESS type code
(or prefix) has been used in the system.
11. CHIME signals violation of the zones when they are disarmed.
12. SILENT ALARM activates in the same situations as the 9. DAY ALARM output. Additionally,
it can signal silent panic alarms.
13. TECHNICAL ALARM – signals alarms from zone types 40-56.
14. ZONE VIOLATIONindicates the violations of zones.
15. VIDEO ON DISARMEDcontrolled by zones with the VIDEO ON DISARMED option enabled.
16. VIDEO ON ARMEDcontrolled by zones with the VIDEO ON ARMED option enabled.
17. READY STATUSindicates whether the system is ready for arming, i.e. whether there are
no violated zones (active when there is no violation).
18. BYPASS STATUSindicates the bypassing of zones.
19. EXIT DELAY STATUSindicates the EXIT DELAY countdown.
20. ENTRY DELAY STATUSindicates the ENTRY DELAY countdown.
21. ARMED STATUS indicates the armed status of partitions.
22. FULL ARMED STATUSactive if all selected partitions are armed.
23. ARM/DISARM BEEP signals:
starting the arming procedure (arming, if the exit delay has not been programmed)
1 pulse,
disarming 2 pulses,
clearing alarm 4 pulses,
denial of arming or arming procedure failure 7 pulses.
The pulse duration is approx. 0.3 seconds.
24. MONO SWITCH controlled by users, zones or timers. Using a code, zone violation or
turning timer on will activate the output for a preprogrammed time.
25. BI SWITCH controlled by users, zones or timers. Depending on the current status, using
a code or violating a zone will activate/deactivate the output. Turning the timer ON
activates the output, and turning the timer OFF deactivates the output.