88 Programming SATEL
Configuration for some devices you can configure additional parameters and options. If
the ABAX 2 device is identified as the ABAX device, its name is shown in parentheses
next to the ABAX device name. Shown in square brackets is information about the number
of zone for which additional parameters are to be programmed if the device takes up more
than one zone.
ADD-200wireless outdoor dusk and temperature detector. You can configure:
sensitivity of the dusk sensor (detection threshold) [first zone],
temperature parameters [second zone]:
threshold type: high (when the temperature rises above the defined value, alarm
will be triggered) or low (when the temperature drops below the defined value,
alarm will be triggered),
temperature,
tolerance.
AGD-100 (AGD-200)wireless glass-break detector. You can configure sensitivity.
AMD-100 (AMD-200) / AMD-101 (AMD-201) wireless magnetic contact. You can select
the active reed switch (not applicable to the AMD-200 / AMD-201 detector, which does
not have two reed switches).
AMD-102 (AMD-202)wireless magnetic contact with input for roller shutter detector. You
can:
select the active reed switch of magnetic contact (not applicable to the AMD-202
detector, which does not have two reed switches) [first zone].
configure parameters of roller shutter input [second zone]:
number of pulses after which the roller shutter input will trigger alarm,
time period during which the defined number pulses must occur for the roller
shutter input to trigger alarm.
AOCD-250 (AOCD-260) wireless outdoor dual technology curtain detector. You can
configure:
sensitivity of the PIR sensor,
sensitivity of the microwave sensor.
AOD-200 (AOD-210) wireless outdoor dual technology motion detector. You can
configure:
sensitivity of the PIR sensor,
sensitivity of the microwave sensor,
sensitivity of the dusk sensor (detection threshold).
APD-100 (APD-200)wireless passive infrared detector. You can configure sensitivity.
APD-100 (APD-200 Pet) wireless passive infrared detector with pet immunity. You can
configure:
sensitivity,
pet immunity option (not applicable to the APD-200 Pet detector, which is immune to
pet movement at all times).
APMD-150 (APMD-250)wireless dual technology detector. You can configure:
sensitivity of the PIR sensor,
sensitivity of the microwave sensor,
manner of operation in the test mode.
ARD-100 (ARD-200)wireless reorientation detector. You can configure sensitivity.