90 Programming SATEL
AGD-100 (AGD-200)
Enter a digit from the 1 to 3 range to set the sensitivity (1 – low , 2 – medium, 3 - high).
AMD-100 (AMD-200) / AMD-101 (AMD-201)
Enter the digit 0 (bottom reed switch) or 1 (side reed switch) to determine which of the two
reed switches is to be active. In the case of the AMD-200 and AMD-201 detectors – do not
configure.
AMD-102 (AMD-202)
Magnetic contact – enter the digit 0 (bottom reed switch) or 1 (side reed switch) to determine
which of the two reed switches is to be active. In the case of the AMD-202 detector – do not
configure.
Roller shutter input – enter 2 digits:
1st digit – number of pulses: from 1 to 8.
2nd digit – pulse validity: 0 (30 seconds), 1 (120 seconds), 2 (240 seconds) or 3 (unlimited
duration).
AOCD-250 (AOCD-260)
Enter 2 digits:
1st digit – sensitivity of PIR sensor: from 1 to 4 (1 – minimum; 4 – maximum).
2nd digit – sensitivity of microwave sensor: from 1 to 8 (1 – minimum; 8 – maximum).
AOD-200 (AOD-210)
Enter 3 digits:
1st digit – sensitivity of PIR sensor: from 1 to 4 (1 – minimum; 4 – maximum).
2nd digit – sensitivity of microwave sensor: from 1 to 8 (1 – minimum; 8 – maximum).
3rd digit – sensitivity of dusk sensor: from 1 to 4 (1 – minimum; 4 – maximum).
APD-100 (APD-200)
Enter a digit from the 1 to 3 range to set the sensitivity (1 – low , 2 – medium, 3 - high).
APD-100 (APD-200 Pet)
Enter 2 digits:
1st digit – sensitivity: 1 (low), 2 (medium) or 3 (high),
2nd digit – pet immunity option: 0 (disabled) or 1 (enabled). In the case of the APD-200 Pet
detector – do not configure.
APMD-150 (APMD-250)
Enter 3 digits:
1st digit – sensitivity of PIR sensor: from 1 to 4 (1 – minimum; 4 – maximum).
2nd digit – sensitivity of microwave sensor: from 1 to 8 (1 – minimum; 8 – maximum).
3rd digit – the way of operation in the test mode: 0 (alarm after motion is detected by both
sensors), 1 (alarm after motion is detected by PIR sensor) or 2 (alarm after motion is
detected by microwave sensor).
ARD-100 (ARD-200)
Enter a number from the 1 to 16 range to determine sensitivity (1 – minimum; 16 –
maximum).