Section 4: Operation and Configuration
Page 4-26
CG4 Series Service Manual
4.13 FACTORY ADJUSTMENT MODE (cont’d)
4.13.1 Output Data of the Factory Adjustment Test Print
The output data of the Factory Adjustment Test Print shows the internal operating parameters of the printer.
These output data are printed in three parts, each with the printing area of 115 mm [3.54”] (Width) x 115 mm
[3.54”] (Pitch), Standard.
First print-out
Second print-out
*1 Printed by LAN model only.
No. Print Item Contents of the print data
1 Model Printer model name
CG408TT(*), CG412TT(*)
CG408DT, CG412DT
*: “T” is printed for thermal
transfer print.
“D” is printed for direct
thermal print.
2 Firm Date Printer F/W creation date YY.MM.DD
3 Firm Version Printer F/W version 39.**.**.**
4 Barcode of firm version
Printer F/W version (Barcode)
Print in CODE39
5 Font Version Font version **.**(R)
6 Barcode of font version Font version (Barcode) Print in CODE39
7 CONT/USB Serial USB serial No. ********
8 Barcode of CONT/USB
Serial
USB serial No. (Barcode) Print in CODE39
No. Print Item Contents of the print data
1 Model Printer model name
CG408TT(*), CG412TT(*)
CG408DT, CG412DT
*: “T” is printed for thermal
transfer print.
“D” is printed for direct
thermal print.
2 CONT/USB Serial USB serial No. ********
3 Interface 1 Interface 1 USB
4 Interface 2 Interface 2 LAN/RS-232C/IEEE1284
5 FROM1 CHECK SUM
Printer F/W: Font: Checksum
(B)**** (P)****
(F)**** (A)****
6 Barcode of FROM1
CHECK SUM
Barcode of Printer F/W: Font:
checksum
Print in CODE39
7 Barcode of MAC
Address *1
Barcode of MAC address. Print in CODE39