Print Zero Setting Results
The result of the automatic zero setting function can
be printed automatically after every belt circuit.
Prerequisite:Parameter H 01 = YES (Auto Zero Active)
Parameter H09 = YES
Tare correction is the total of all zero point changes;
total tare additionally includes the basic tare.
Values correspond to same-name parameters
D 03/05.
Status Report
The status report can be printed at any time.
Reported are previous events, calibration results, and
SPC measurement values, e.g. feed rate variance.
SPC = Statistic Process Control
For individual data, see “Service Values” item.
GT Call function distributor and select
“Status Report” function.
f Start function.
N Abort printing at any time.
Zero Set before:
Zero point corrected by taring program or
manual/automatic zero setting.
Voltage ON-time:
Total voltage ON-time.
Feeder ON-time:
Total ON-time of conveyor belt and INTECONT.
Last password entry on:
Date of last password input for start of a service function
or parameter change.
Latest matkor change:
The matkor parameter lets you change feed rate and
totalization range.
SPC time:
Measuring time for SPC values “Qmax” and “TQ < MIN”.
0837
VBW INTECONT PLUS
Control
BV-H2214 GB 14
Technische
Redaktion PDE-RD
Transmission to third parties and reproduction of
this documentation are not permitted. Schenck
Process GmbH reserves all rights of ownership
and copyrights.
Print Zero Setting Results
Total Tare [kg/m] 50,23 Tare Correction T [kg/m] 1,56
STATUS REPORT INTECONT PLUS
25.11.02 13:37:12
Software : VBW 20600-01 2482
Hardware version : 1
Option card version : 1
Station address : 1
-------------------------------
Latest Report of: 25.11.02 12:13:13
------------ -------------------
SPC values:
Zero Set before : 4086 min
Voltage ON-time : 68 h
Feeder ON-time : 68 h
Latest password entry of : 22.11.02 17:02:12
Latest matkor change : 15.11.02 15:02:34
K05 SPC Time : 1 h
K06 SPC Filter : 1.00 h
Feed rate
Mean value Imitt : 0.15 %
Variance : 0.09 %
Belt load Q MAX : 0 %
Time Q MIN : 0 %
Totalizer 3 : 510 t
Belt skew : 0.00 %
Belt Drift : 0.00 cm
Latest taring results (max. 5) T in % of Qnenn
22.11.02 16:04:05 : 12.99 %
21.11.02 16:11:22 : 30.75 %
21.11.02 16:10:53 : 33.40 %
22.11.02 16:05:22 : 12.99 %
22.11.02 16:04:43 : 12.99 %
Test weight check of 16.06.03 16:23:17
25.11.02 09:06:28
Set/Act 0.9643
N05 BIC Active NO
Events since power on
1 * H03 v> MAX
1 * C07 Set Time To Zero
1 * E01 Power Failure