Block A : Dialog Behaviour
A01 Language
Range: DEUTSCH
ENGLISH*
AMERICAN ENG*
FRANCAIS
ESPANOL
ITALIANO
Default: DEUTSCH
Selection applies to all displays, error messages and
parameters.
* identical
A02 Units
Range: SI
NON-SI
Default: SI
Convert displays and parameter inputs from SI units
into American units.
American Units SI Units Conversion *
lb
t
f
inch
kg
t
m
cm
1 lb = 0.453593 kg
1 t = 0.907185 t = 2000 lb
1 f = 0.3048 m
1 inch = 2.54 cm
* also applicable to compound units, e.g. kg/hr
A03 Password
Range: 1000 - 9999 Default: 07734 o 7734
The password that secures the INTECONT keyboard
access to parameters and adjustment functions
can now be changed. The changed password is
shown encoded in the parameter dialog and
EasyServe. The default value 07734 (or 7734)
generates the return display 26574 (this process is
identical to DISOCONT).
Note:
If you forget your password, you have to change your
password with EasyServe or report the shown value of
the parameter A03 to Schenck Service to find out the
appropriate password
A04 Second password
Range: 1000 - 9999 Default: 2889
The password for using a specific system. This
password allows you to protect the basic functions in
the function distributor (see above). It does not allow
access to parameters or adjustment functions. The
changed password is also shown encoded. The
default value 2889 generates the return display
14389.
Note: If you forget the second password, you can
enter a new password in the A04 parameter using the
standard password
A05 Feeder ON/OFF
Range: active
not active
Password
2. Password
Confirm
Default: active
You can use this parameter to control access to the
basic functions of ON/OFF prefeeder.
You have the options below::
active: Access is always allowed.
not active: Access is never allowed. This
function is not visible in the
distributor.
Password: Access is available with the
standard password (A03).
Second
Password: Access is available with the new
second password (A04)..