Block D : Calibrat. Results
D01 Nominal Belt Load
No input possible Default: 111,11 kg/m
computed from nominal data B 02 and B 05
used as reference value for limit values and zero
setting program.
D02 Span Correction
Range: 0,5000...2,0000 Default: 1,0000
proportionally influences measurement of belt load q.
q(corrected) = q(measured) · D 02
used to correct measuring system through check with
material.
D03 Total Tare
No input possible Default: 0,00 kg/m
Total tare = basic tare + tare correction
D04 Basic Tare N
No input required
max. 10000 kg/m
Default: 0,00 kg/m
Result of taring program.
D05 Tare Correction T
No input required
max. +- 1000 kg/m
Default: 0,00 kg/m
Result of manual or automatic zero setting program
After every taring operation, D 05 is set to 0.
D06 Belt Circuit Char
No input required
max. 9E6
Default: 1000000 I/U
Result of basic calibration program “Imp/Belt Circuit”.
Determines cycle of setting programs.
Divided by Parameter B 04 (vs Charact.Val.), belt
length in m results.
Attention!
When entering Parameters D 02 ... D 05 in manual, start
with D 02.
0837
INTECONT PLUS VBW
Parameterization
BV-H2214 GB 55