EasyManuals Logo

Schenck process Intecont Plus Belt Weigher User Manual

Schenck process Intecont Plus Belt Weigher
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
H08 Print Result
Range: NO
YES Default: NO
Print zero setting result after every belt circuit.
H09 ZDO Active
Range: NO
YES Default: NO
Activates Zero Drop Out function (see H 10).
H10 ZDO Limit
Range: 0.0...10.00 %Q Default: 1.00 %Q
Reference: Nominal Belt Load D 01
If ZDO function is active and belt load exceeds the
defined limit, feed rate measurement and totalization
are suppressed.
No symbol appears on display.
H11 Zero Set Diff.
Range: 0.00...100.00 %F Default: 5.0 %F
Reference: Nominal Belt Load D 01
Indicates the difference between two consecutive
manual or automatic zero setting operations.
Excess is reported by message C9.
H12 Tare Diff. > MAX C9
Range: WARNING 2
WARNING1
IGNORE
ALARM Default: WARNING 2
Manual or automatic zero setting has exceeded
difference H 11.
Correction is acquired save in case of ALARM
messages.
0837
VBW INTECONT PLUS
Parameterization
BV-H2214 GB 60
Technische
Redaktion PDE-RD
Transmission to third parties and reproduction of
this documentation are not permitted. Schenck
Process GmbH reserves all rights of ownership
and copyrights.
Result autom. zero setting
Total Tare [kg/m] 50,23 Tare [kg/m] 1,56
(D 03) (D 05)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schenck process Intecont Plus Belt Weigher and is the answer not in the manual?

Schenck process Intecont Plus Belt Weigher Specifications

General IconGeneral
BrandSchenck process
ModelIntecont Plus Belt Weigher
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals