4.9 Line choke
Install the line choke close to the application inverter but outside the minimum clear-
ance for cooling. The line choke must not be heated by the exhaust air of the applica-
tion inverter.
• Install the line choke before the line filter.
• The connection cable between line choke and line filter does not have to be shiel-
ded.
• Limit the length of the cable between the line choke and the line filter to the abso-
lute minimum needed.
4.10 Line filter
• Install the line filter close to the application inverter but outside the minimum clear-
ance for cooling. The line filter must not be heated by the exhaust air of the appli-
cation inverter.
• Do not wire any other consumers between the line filter and the application in-
verter.
• The connection cable between line filter and application inverter does not have to
be shielded.
• Limit the length of the cable between the line filter and the application inverter to
the absolute minimum needed.
• Do not switch between the NF... line filter and inverter.