4
Installation
Mechanical installation
Operating Instructions – MOVIDRIVE
®
modular
55
4.3.2 Minimum clearance and mounting position
When installing the modules in the control cabinet, observe the following:
• To ensure unobstructed cooling, leave a minimum clearance of 100 mm above
and below the module housings. Make sure air circulation in the clearance is not
impaired by cables or other installation equipment.
• Make sure that the devices are not subjected to heated exhaust air from nearby
components.
• The axis system must be assembled without gaps.
• Install the modules only vertically. You must not install them horizontally, tilted or
upside down.
INFORMATION
Special bending spaces are required according to EN 61800‑5‑1 for cables with a
cross section of 10mm
2
and larger. This means the clearance must be increased if
required.
24748536/EN – 11/2017