4
Installation
Terminal assignment
Operating Instructions – MOVIDRIVE
®
modular
133
Representa-
tion
Terminals Connection Brief description motor encoder
HIPERFACE
®
and SEW‑EURODRIVE en-
coder (RS485)
X15_1:1 X15_2:1 A (COS +) (K1) Signal track A (COS+) (K1)
X15_1:2 X15_2:2 B (SIN +) (K2) Signal track B (SIN+) (K2)
X15_1:3 X15_2:3 Reserved –
X15_1:4 X15_2:4 DATA+ Data line RS485
X15_1:5 X15_2:5 Reserved –
X15_1:6 X15_2:6 -TEMP_M Motor temperature evaluation
X15_1:7 X15_2:7 Reserved –
X15_1:8 X15_2:8 GND Reference potential
X15_1:9 X15_2:9 A (COS -) (K1) Negated signal track A (COS-) (K1)
X15_1:10 X15_2:10 B (SIN -) (K2) Negated signal track B (SIN-) (K2)
X15_1:11 X15_2:11 Reserved –
X15_1:12 X15_2:12 DATA- Data line
X15_1:13 X15_2:13 U
S24VG
24 V encoder supply
X15_1:14 X15_2:14 +TEMP_M Motor temperature evaluation
X15_1:15 X15_2:15 U
S12VG
12 V encoder supply
24748536/EN – 11/2017