EasyManua.ls Logo

SEW-Eurodrive MOVIDRIVE MDA90A-0160-503-X-S00

SEW-Eurodrive MOVIDRIVE MDA90A-0160-503-X-S00
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
Operation
Axis module fault
Operating Instructions – MOVIDRIVE
®
modular
189
Subfault: 25.14
Description: Calibration data of power section – version conflict
Response: Emergency stop + output stage inhibit
Cause Measure
Wrong version of calibration data of power section. Contact the SEW-EURODRIVE Service.
Subfault: 25.15
Description: Calibration data of control electronics – version conflict
Response: Emergency stop + output stage inhibit
Cause Measure
Wrong version of calibration data of control electronics Contact the SEW-EURODRIVE Service.
Subfault: 25.16
Description: Calibration of power section – CRC error
Response: Emergency stop + output stage inhibit
Cause Measure
Faulty calibration data of power section. Contact the SEW-EURODRIVE Service.
Subfault: 25.17
Description: Calibration data of control electronics – CRC error
Response: Emergency stop + output stage inhibit
Cause Measure
Faulty calibration data of control electronics Contact the SEW-EURODRIVE Service.
Subfault: 25.18
Description: QA data power section – CRC error
Response: Warning
Cause Measure
Faulty quality assurance data of power section. Contact the SEW-EURODRIVE Service.
Subfault: 25.19
Description: QA data control electronics – CRC error
Response: Warning
Cause Measure
Faulty quality assurance data of control electronics Contact the SEW-EURODRIVE Service.
Subfault: 25.20
Description: Initialization error – basic unit memory
Response: Emergency stop + output stage inhibit
Cause Measure
Initialization error of the basic unit memory. Contact the SEW-EURODRIVE Service.
Subfault: 25.21
Description: Runtime error – basic unit memory
Response: Emergency stop + output stage inhibit
Cause Measure
Runtime error in memory of basic unit. Contact the SEW-EURODRIVE Service.
Subfault: 25.30
Description: Initialization error – replaceable memory module
Response: Output stage inhibit
System state: Fault ackn.with CPU reset
Cause Measure
Initialization error of the replaceable memory module. Contact the SEW-EURODRIVE Service.
Subfault: 25.31
Description: Runtime error – replaceable memory module
Response: Output stage inhibit
System state: Fault ackn.with CPU reset
Cause Measure
Runtime error of the replaceable memory module. Contact the SEW-EURODRIVE Service.
24748536/EN – 11/2017

Table of Contents

Related product manuals