MX-2300/2700 N/G ADJUSTMENTS 6 – 26
14-A Scan image magnification ratio adjustment
(Main scanning direction) (Document table
mode)
1) Place a scale on the document table as shown in the figure
below.
2) Enter the simulation 48-1 mode.
3) Make a normal copy and obtain the copy magnification ratio.
Press [CLOSE] key and shift from the simulation mode to the
copy mode and make a copy.
4) Check that the copy magnification ratio is within the specified
range (100 ± 1.0%).
If the copy magnification ratio is within the specified range (100
± 1.0%), the adjustment is completed. If the copy magnification
ratio is not within the specified range, perform the following
procedure.
5) Change the CCD (MAIN) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy magnifica-
tion ratio in the sub scanning direction is increased.
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.1%.
Repeat the procedures 3) – 5) until the copy magnification
ratio is within the specified range (100 ± 1.0%).
14-B Scan image magnification ratio adjustment
(Sub scanning direction) (Document table
mode)
1) Place a scale on the document table as shown in the figure
below.
2) Enter the simulation 48-1 mode.
3) Make a normal copy and obtain the copy magnification ratio.
Press [CLOSE] key and shift from the simulation mode to the
copy mode and make a copy.
4) Check that the copy magnification ratio is within the specified
range (100 ± 1.0%).
If the copy magnification ratio is within the specified range (100
± 1.0%), the adjustment is completed. If the copy magnification
ratio is not within the specified range, perform the following
procedure.
5) Change the CCD (SUB) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy magnifica-
tion ratio in the sub scanning direction is increased.
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.1%.
Repeat the procedures 3) – 5) until the copy magnification ratio is
within the specified range (100 ± 1.0%).
15 Scan image magnification ratio
adjustment (RSPF mode) (Refer to
the MX-RPX1 SM.)
15-A Scan image magnification ratio adjustment
(Main scanning direction) (RSPF mode)
(Refer to the MX-RPX1 SM.)
15-B Scan image magnification ratio adjustment
(Sub scanning direction) (RSPF mode)
(Refer to the MX-RPX1 SM.)
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
CLOSE
0
A
:
Axx
Bxx
Cxx
Dxx
㧧 CCD(MAIN)
㧧 CCD(SUB)
SPF(MAIN)
SPF(SUB)
SIM ULATI ON
NO.48-01
MAGNIFICATION ADJUSTMENT
xx
1 99
O
K
TEST
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
CLOSE
0
:
Axx
Bxx
Cxx
Dxx
㧧 CCD(MAIN)
㧧 CCD(SUB)
SPF(MAIN)
SPF(SUB)
SIM ULATI ON
NO.4 8-01
MAGNIFICATION ADJUSTMENT
xx
1 99
O
K
TEST
10 20 90
100 110
10 20 90
100 110
10 20 90
100 110
Copy magnification ratio
(Original dimension Copy dimension)
Original dimension
=
x 100 [%]
(Example 1)
Copy A
(Shorter than
the original)
Scale
(Original)
(Example 2)
Copy B
(Longer than
the original)