219
EAN Non-PLU code format (ARTICLE
EAN NON-PLU ....... PGM2)
Format table: Format 1 through Format 12
EAN-13 type EAN-8 type
C
D
Free formatFlag
(02 or 20-29)
Field 2Field 1
Free format area
Price check digit
2
C
D
Free format
Flag
(1) Select the PGM2 mode and touch the [SETTING] to perform the programming.
(2) Touch the [ARTICLE] button to display the menu, and touch the [EAN NON-PLU] button to display the
format list.
(3) Touch or enter the format number and touch the [ENTER] key to program the format.
(4) Touch the required programming item, and enter or select each parameter and touch the [ENTER] key.
Repeat this step (4) satisfactorily.
(5) To terminate the programming, touch the [EXIT] key.
Text Parameter
EAN8: EAN-8 format code
TYPE OF CODE EAN13: EAN-13 format code
(UPC-A is “0n”of EAN13)
SYSTEM CODE n:EAN8, nn:EAN13(UPC-A)
LENGTH FIELD#1 Length of field 1 (0 to 9)
LENGTH FIELD#2 Length of field 2 (0 to 9)
FIELD#1 DATA FREE (fixed “FREE”)
Meaning of field 2
FIELD#2 DATA QUANTITY: quantity
PRICE: Price
Price Check digit
PRICE CHECK DIGIT YES: Use the price check digit
NO: Not use the price check digit
TAB TAB or decimal point of field 2 : 3/2/1/0

Table of Contents