282
BCR (SCANNER) (DEVICE CONFIG
BCR (SCANNER) ....... PGM2)
(1) Select the PGM2 mode and touch the [SETTING] to perform the programming.
(2) Touch the [DEVICE CONFIG] button to display the menu, and touch the [BCR (SCANNER)] button to
program details.
(3) Select the required programming item, and enter or select each parameter, then touch the [ENTER]
key.
Repeat this step (3) satisfactorily.
(4) To terminate the programming, touch the [EXIT] key.
Text Parameter
CHANNEL# 0 - 5: 0means no RS-232 channel is assigned.
Transmission data rate (Baud rate)
BAUD RATE
19200 bps:
9600 bps:
4800 bps:
DATA BITS
7 bits:
8 bits:
NON: Non-parity
PARITY ODD: Odd parity
EVEN: Even parity
STOP BIT
1 bit:
2 bits:
SCALE (DEVICE CONFIG
SCALE ....... PGM2)
(1) Select the PGM2 mode and touch the [SETTING] to perform the programming.
(2) Touch the [DEVICE CONFIG] button to display the menu, and touch the [SCALE] button to program
details.
(3) Select the required programming item, and enter or select each parameter, then touch the [ENTER]
key.
Repeat this step (3) satisfactorily.
(4) To terminate the programming, touch the [EXIT] key.
Text Parameter
CHANNEL# 0 - 5: 0means no RS-232 channel is assigned.