Figures and Tables
Fig. 10-1: Meaning of selection 1, 2 and 3 in the reading area diagram
related to depth of focus diagram. .................................................................. 85
Fig. 10-2: Depth of field ranges of the CLV650 line scanner with front reading window:
Resolutions 0.25 mm (9.8 mil), 0.35 mm (13.8 mil), 0.5 mm (19.7 mil)
and 1.0 mm (39.4 mil) ..................................................................................... 86
Fig. 10-3: Depth of field ranges of the CLV650 line scanner with front reading window:
min. und max. reading distance depending on the focus position
and the aperture angle with a resolution of 0.25 mm (9.8 mil) ................... 87
Fig. 10-4: Depth of field ranges of the CLV650 line scanner with front reading window:
min. und max. reading distance depending on the focus position
and the aperture angle with a resolution of 0.35 mm (13.8 mil) ................. 88
Fig. 10-5: Depth of field ranges of the CLV650 line scanner with front reading window:
min. und max. reading distance depending on the focus position
and the aperture angle with a resolution of 0.5 mm (19.7 mil) ................... 89
Fig. 10-6: Depth of field ranges of the CLV650 line scanner with front reading window:
min. und max. reading distance depending on the focus position
and the aperture angle with a resolution of 1.0 mm (39.4 mil) ................... 90
Fig. 10-7: Depth of field ranges of the CLV650 line scanner with oscillating mirror
(side reading window):
Resolutions 0.25 mm (9.8 mil), 0.35 mm (13.8 mil), 0.5 mm (19.7 mil)
and 1.0 mm (39.4 mil) ..................................................................................... 91
Fig. 10-8: Depth of field ranges of the CLV650 line scanner with oscillating mirror
(side reading window): min. und max. reading distance depending
on the focus position and the aperture angle
with a resolution of 0.25 mm (9.8 mil) ........................................................... 92
Fig. 10-9: Depth of field ranges of the CLV650 line scanner with oscillating mirror
(side reading window): min. und max. reading distance depending
on the focus position and the aperture angle
with a resolution of 0.35 mm (13.8 mil) ........................................................ 93
Fig. 10-10: Depth of field ranges of the CLV650 line scanner with oscillating mirror
(side reading window): min. und max. reading distance depending
on the focus position and the aperture angle
with a resolution of 0.5 mm (19.7 mil) ........................................................... 94
Fig. 10-11: Depth of field ranges of the CLV650 line scanner with oscillating mirror
(side reading window): min. und max. reading distance depending
on the focus position and the aperture angle
with a resolution of 1.0 mm (39.4 mil) ........................................................... 95
Fig. 10-12: Depth of field ranges of the CLV651 line scanner with front reading window:
Resolution 0.5 mm (19.7 mil) and inclination angle 0°/45° ....................... 96
Fig. 10-13: Depth of field ranges of the CLV651 line scanner with front reading window:
Resolution 0.5 mm (19.7 mil); inclination angle 0°;
aperture angle 25°/55°................................................................................. 97
Fig. 10-14: Depth of field ranges of the CLV651 line scanner with front reading window:
Resolution 0.5 mm (19.7 mil); inclination angle 45°;
aperture angle 25°/55°................................................................................. 98
Fig. 10-15: Depth of field ranges of the CLV651 line scanner with oscillating mirror
(side reading window): Resolution 0.5 mm (19.7 mil)
and inclination angle 0°/45°.......................................................................... 99
Fig. 10-16: Depth of field ranges of the CLV651 line scanner with oscillating mirror
(side reading window): Resolution 0.5 mm (19.7 mil);
inclination angle 0°; aperture angle 25°/55° ...........................................100
Fig. 10-17: Depth of field ranges of the CLV651 line scanner with oscillating mirror
(side reading window): Resolution 0.5 mm (19.7 mil);
inclination angle 45°; aperture angle 25°/55° .........................................101

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Advanced CLV65 Series and is the answer not in the manual?

SICK Advanced CLV65 Series Specifications

General IconGeneral
BrandSICK
ModelAdvanced CLV65 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals