Stored movement time in seconds (attribute ID 6Bh)
•
Stored operating time in seconds (attribute ID 6Ch)
The limit values can be changed via the “AuthorizedClient” user (see "Limits",
page 100).
6.2 Parameterization
The encoder can be parameterized with the help of this page. The parameterization
sets the attributes of the position sensor object (see table 24, page 29). The parame‐
terization options depend on who has logged in as a user.
After a new parameter has been entered, press the [Enter] key. The parameter is
written into the volatile memory of the encoder.
NOTE
Only the last changed parameter is written into the volatile memory by pressing the
[Enter] key. If several values are to be changed (e.g. the lower and upper speed limits),
press the [Enter] key after each entry.
The following parameterization options are available without logging in:
•
Overview
•
Units
•
Preset
The following parameterization options are available after logging in as the “Authorized‐
Client” user:
•
Scaling
•
Round axis functionality
•
Changing preset value
•
Limits
•
Reset
Log in
For parameterization, the following access data can be used for login:
•
User: AuthorizedClient
•
Password: enc123
Figure 107: Log in
Changing the password
NOTE
For data security reasons and to avoid unauthorized access, changing the password at
the first login is recommended.
1. Go to Benutzer and click on the Ändere Passwort link.
6 CONFIGURATION USING THE INTEGRATED WEB SERVER
96
O P E R A T I N G I N S T R U C T I O N S | AFS/AFM60 EtherNet/IP 8014213/1EF3/2021-12-08 | SICK
Subject to change without notice